Skip to content

Mon–Sat 7 AM–6 PMMon–Sat 7–6

77 Copperfield Row, Tampa · Serving Hillsborough County

CopperfieldHeating & Air · Tampa Call now(656) 236-2374 Request service
A technician with a flashlight inspecting the top of an outdoor AC condenser beside a white-sided house

AC repair in Tampa

No cold air, ice on the line, or a system that quit by itself. We measure first, then fix what the readings say.

  • Diagnostic charge told on the phone
  • Readings on your report
  • Price agreed before work

Measured, then priced

Readings first. No guessing from the thermostat or the driveway.

Nothing sold on a hunch

If a small part fixes it, a small part is the repair we write down.

A person answers

The office picks up Monday to Saturday, and calls you back to agree a time.

Licensed & insured

Cooling and heating, on every truck.

Sound familiar?

Signs your AC needs a look

Each one has a short list of causes, and one reading usually tells them apart.

It runs and runs, and never gets cool

Low charge, a dirty coil or poor airflow. The split between supply and return air says which.

Ice on the copper line

A symptom with two parents: not enough air, or not enough refrigerant. It has to thaw before anyone can read it.

It shut itself off

Very often the float switch on a blocked condensate drain, doing exactly its job. Nothing is broken.

A woman reaching up to adjust the thermostat on a stone-clad wall in her living room

Before you call

Three things worth checking yourself

If one of these is it, you've fixed it for nothing, and we'd rather that than charge you for the drive.

  • The filter. If it's gray and you can't see light through it, that alone explains a lot of no-cooling calls.
  • The breaker for the outdoor unit, and the switch by the air handler that looks like a light switch and isn't.
  • The condensate drain. If the pan is holding water, the float switch has probably shut the system off on purpose.

What we measure

What gets read on a no-cooling call

The same readings on every call, as found and as left, printed beside the number they should be.

Supply/return split16–22°F

Return minus supply. Much lower and the system isn't doing the work.

Superheat8–12°F

The target on a TXV system. How a charge is actually checked.

Subcooling10±2°F

Read with superheat. Together they tell a leak from an airflow problem.

Static pressure0.50in. w.c.

Total external. Above it, the blower is fighting the ducts.

Run capacitor±6%

Measured against the rating printed on its own case.

Amp draw< RLA

Compressor and fan against the data plate.

Low side118psig

With its saturation temperature, not on its own.

Condensate floatDry

Lifted and tested, not looked at.

How we do it

How an AC repair goes

In this order, every time.

  1. Thaw and look

    If it's iced, fan on and cooling off. Filter, coil face, return and drain get checked while it thaws.

  2. Measure

    Pressures, superheat, subcooling, the split, static pressure, capacitor and amps.

  3. Price it

    The fix, the part and the labor, written down and agreed before we start.

  4. Fix and read back

    Repaired, then read again, so you can see it worked.

What it costs

What an AC repair costs in Tampa

What moves the price

  • What failed. A float switch or a clogged drain line is a small job; a coil or compressor is not.
  • Whether there's a leak. A low charge means a hole, and finding it is the part that takes time.
  • Access. An attic air handler takes longer than one in the garage.
  • Parts on the truck. Most common parts are; some have to be ordered.

The visit charge, up front

There is a diagnostic charge for a service call, and we tell you what it is on the phone before anyone drives out. You keep the written report whether or not you go ahead.

Repairs are priced as a job, part and labor named, and agreed before we start.

Request service

The details

The parts of an AC repair most people are never told

Open any of these. They're the reasons our reports have numbers on them.

Ice on the line is a symptom, and it has two parents

Ice forms because the evaporator coil is running below freezing, and there are two ways to get there: not enough air moving across the coil, or not enough refrigerant inside it. Both end in the same white lump on the copper, and the ice then makes it worse by blocking the airflow.

That's why the first thing we do on an iced system is usually nothing at all. You can't read pressures through ice, and anyone who names a cause while it's still frozen has decided in advance what they're selling.

A dirty filter and a dirty coil fail the same way

Both restrict air. Less air across the coil means the refrigerant can't boil off, the coil temperature falls and the moisture on it freezes. One costs a few dollars and the other is a couple of hours with a coil cleaner.

A filter can cause it while looking spotless, too: a one-inch pleated filter with a very high MERV rating restricts a system built for low resistance on the day it's fitted.

The condensate drain, and the switch that shut your system off

An air handler pulls several gallons of water a day out of Florida air. That water leaves through a small PVC line, and the line blocks. When it does, the pan fills and the float switch stops the system on purpose, before the water reaches your ceiling.

We clear the line properly, check the trap, slope and vent, test the switch by lifting it and tell you why it blocked.

Capacitors: the cheapest thing that fails, and the easiest to oversell

A run capacitor genuinely is the most common failure on a residential system, which makes it the easiest thing to fit to a system that didn't need it. The defense is a number: every capacitor is stamped with its rating and tolerance, and a meter reads it in ten seconds.

Ours goes on the report whether it's replaced or not. If somebody swapped yours, it's fair to ask what it read before it came out.

Hard-start kits, honestly

A hard-start kit gives the compressor more torque for the first fraction of a second. It genuinely helps on a long line set or a weak supply, and it will usually get a tiring compressor through a season.

The second use is fine as long as it's said out loud: it's a walking stick, not a cure. When we fit one for that reason, the report says so in those words.

Questions

AC repair questions

My AC needs a pound of refrigerant every summer. Can you just add it?

No. A refrigerant circuit is sealed, and nothing uses refrigerant up. If it's low, it's leaking, and adding more sends the new gas out of the same hole at your expense. Knowingly venting refrigerant is also illegal under Section 608 of the Clean Air Act.

We find the leak instead. It's often a Schrader core or a flare fitting, and those are cheap.

The coil is frozen solid. Is that low refrigerant?

Maybe. It's equally likely to be airflow. The readings separate the two, and you can't take them until the coil has thawed, so switch cooling off and leave the fan running.

Somebody told me I need a capacitor. Do I?

Possibly. Ask for the number: a capacitor is stamped with its rating and tolerance, usually ±6%. If it measures inside that, it's fine.

Do you charge to come out?

Yes, there's a diagnostic charge, and it's told to you on the phone before we come. It covers the diagnosis and the readings, and you keep the report either way.

A white single-story Florida home with a dark tile roof, tall royal palms and a curving paver path

Tampa · Hillsborough County

Get somebody out with gauges on the truck.

Tell us what it's doing. We'll say what to check first and whether it can wait, and if it can't, the office will call you to agree a time.

Bots On Staff · built for shops like yours

We built this one. The next one has your name on it.

What the chat on this page is doing

Say there is no cold air and it has you check the float switch on the condensate drain first. If that drain is blocked the system stops on purpose — nothing is broken.

It takes a name and a number and hands it straight over. Nothing here is held, booked or confirmed, and it will not price the job.

What it costs

website from $1,195, paid oncebots from $149 a month

The whole number, on the page. We build your first page free, on your own name, in 12–48 hrs — you look at it before any money moves.

What comes with it
  • Your Google Business Profile set up
  • Your local directory listings
  • A chat on your website that answers customers day and night
  • Every lead emailed to you
  • Your marketing platform: make posts to your website and your Google Business Profile, all from one place
  • Continuous updates for AI search: your posts go from the platform to your website and your Google Business Profile, keeping your business current for the people searching and the assistants that read it
  • One platform for your posts and leads, where your customers come from, and your ads if you add Google Ads
  • If you add Google Ads: see your Google Ads analytics, your spend each day and your keywords, day by day or across any date range, from the same platform
  • Every bot on staff for your trade
  • Your posts drafted for you to approve, for your website and Google Business Profile. Nothing goes out until you say so
  • The Ad Manager checks your Google Ads spend every morning, if you run ads
  • The referral program
  • The lead form, wired to you
  • The staff tools: scheduling, crew and documents
  • 30 minutes a month of website and Google Business Profile work (Starter has 15 minutes). It does not roll over to the next month.

It does not roll over to the next month.

Mini $49 a month (no bots) · Starter $149 a month (starting with bots) · Growth $249 a month (full bots). The website is priced on its own, paid once.

What you own

The website is yours to keep, on your own domain. The chat and the marketing stop with the service.

Thirty days’ notice, any time. No year, no lock.

One company per area. When yours is taken, it’s taken.

See every price How a build works →